logo
> 상품 >
케이블 결함 탐지기
>
Portable Cable Fault Locator and Test Equipment for Rough Measurement with ≥7500V High Voltage

Portable Cable Fault Locator and Test Equipment for Rough Measurement with ≥7500V High Voltage

제품 상세정보:
원래 장소: 시안 산시 중국
브랜드 이름: XZH TEST
인증: ISO/CE
모델 번호: XHHG521A
상세 정보
원래 장소:
시안 산시 중국
브랜드 이름:
XZH TEST
인증:
ISO/CE
모델 번호:
XHHG521A
강조하다:

High Light

강조하다:

≥7500V Cable Fault Locator

,

Rough Measurement Test Equipment

,

Portable Cable Tester

Trading Information
최소 주문 수량:
1세트
포장 세부 사항:
목재 포장
배달 시간:
5-8 근무일
지불 조건:
티/티
공급 능력:
3000단위/년
제품 설명
XHHG521A
The cable outer sheath fault tester is designed based on the Murray bridge principle and can be used to locate the breakdown points of various wires and cables, as well as defects that are not broken down but have low insulation resistance values.
Key Features
  • Designed for rough measurement applications
  • Reliable test equipment for cable maintenance
  • Professional-grade fault location capabilities
Technical Specifications
Measurement Type Rough measurement
Open circuit voltage ≥7500V
Application Cable fault location
Equipment Type Test equipment

The cable outer sheath fault tester is particularly suitable for:

1. High-resistance breakdown points in cables after installation, especially linear high-resistance breakdown points that are difficult to burn into low-resistance conditions, such as linear high-resistance breakdowns at cable joints.

2. Flashover-type breakdown points, where the constant current source can maintain the arc after breakdown, a stable current flows through the bridge, and the bridge has sufficient sensitivity.

3. Defects that have not yet broken down but have low resistance, such as insulation defects where a megohmmeter reveals a low cable resistance value, but the cable does not break down under operating voltage.


The distances from both ends of the cable under test to the breakdown point are L1 and L2, respectively. The total length of the cable is L, and the corresponding core resistances are R1 and R2.

Clearly, after connecting to the bridge circuit, the following circuit is formed.

Portable Cable Fault Locator and Test Equipment for Rough Measurement with ≥7500V High Voltage 0

The cable outer sheath fault tester is particularly suitable for:

1. High-resistance breakdown points in cables after installation, especially linear high-resistance breakdown points that are difficult to burn into low-resistance conditions, such as linear high-resistance breakdowns at cable joints.

2. Flashover-type breakdown points, where the constant current source can maintain the arc after breakdown, a stable current flows through the bridge, and the bridge has sufficient sensitivity.

3. Defects that have not yet broken down but have low resistance, such as insulation defects where a megohmmeter reveals a low cable resistance value, but the cable does not break down under operating voltage.

Portable Cable Fault Locator and Test Equipment for Rough Measurement with ≥7500V High Voltage 1