logo
> 상품 >
케이블 결함 탐지기
>
TDR Cable Fault Locator with Self-discharge and One-click Mode Switching for Accurate Fault Detection

TDR Cable Fault Locator with Self-discharge and One-click Mode Switching for Accurate Fault Detection

제품 상세정보:
원래 장소: 중국 산시성 시안
브랜드 이름: XZH TEST
인증: ISO CE
모델 번호: XHHD523
상세 정보
원래 장소:
중국 산시성 시안
브랜드 이름:
XZH TEST
인증:
ISO CE
모델 번호:
XHHD523
강조하다:

High Light

강조하다:

Self-discharge Cable Fault Locator

,

One-click mode switching TDR Cable Tester

,

TDR Cable Fault Detector

Trading Information
최소 주문 수량:
1세트
포장 세부 사항:
목재 포장
배달 시간:
5-8 근무일
지불 조건:
티/티
공급 능력:
3000단위/년
제품 설명
XHHD523
Advanced cable fault detection system featuring Time Domain Reflectometry (TDR) technology for precise fault location.
With the comprehensive rollout of urban power grid upgrades, many power supply bureaus, construction companies, and even design units are encountering XLPE cables with voltage levels of 110kV and above for the first time. Due to time constraints and lack of experience, many cables fail the withstand voltage test (10kV/1min) after installation. Currently, most outer sheaths use HDPE sheathing material, which has passed the DC 25kV/5min withstand voltage test in the factory, with leakage current as low as tens of μA. Therefore, most defects after installation are caused by external force damage during installation, including backfilling and cover plate application. Defects after operation typically include termite bites; water ingress into the grounding box; deterioration of existing defect points; and moisture penetration at grounding wire branching points leading to a decrease in insulation resistance. Sometimes, due to excessive cable burial or complex surrounding conditions, locating the defect is extremely difficult, and some defects remain unresolved for many years, leaving hidden dangers for operation.

Product Features


1. Automatic overcurrent, overvoltage, and overheat protection;

2. Zero-position start protection for enhanced safety and reliability;

3. Unique self-discharge design: the high voltage itself drops to zero as soon as the high-voltage output is cut off;

4. Dual pointer display for current and voltage, providing clear and intuitive readings;

5. One-button switching between positioning mode and withstand voltage mode for convenience and speed;


TDR Cable Fault Locator with Self-discharge and One-click Mode Switching for Accurate Fault Detection 0

TDR Cable Fault Locator with Self-discharge and One-click Mode Switching for Accurate Fault Detection 1