logo
> 상품 >
케이블 결함 탐지기
>
12 Inch Windows System ICE LV TDR Cable Fault Locator

12 Inch Windows System ICE LV TDR Cable Fault Locator

제품 상세정보:
원래 장소: 시안 산시 중국
브랜드 이름: XZH TEST
인증: ISO
모델 번호: XHGG501A2
상세 정보
원래 장소:
시안 산시 중국
브랜드 이름:
XZH TEST
인증:
ISO
모델 번호:
XHGG501A2
표시하다:
12.1인치 터치 컬러 LCD 화면
샘플링 주파수:
400MHz
낮은 전압 펄스 진폭:
400V
강조하다:

High Light

강조하다:

ICE LV TDR Cable Fault Locator

,

TDR Cable Fault Locator 12" Windows System

,

12.1-inch touch color LCD screen

Trading Information
최소 주문 수량:
1세트
포장 세부 사항:
목재 포장
배달 시간:
5-8 근무일
지불 조건:
티/티
공급 능력:
3000단위/년
제품 설명

Description

The 12" Windows System ICE LV TDR Cable Fault Locator is a precision instrument designed for detecting and locating faults in low-voltage cables. Its advanced Time Domain Reflectometry (TDR) technology provides accurate fault detection for efficient cable maintenance and troubleshooting.

Know more about power cables

 Power cables can be divided into:

Low-voltage cables (cables with voltage levels of 6kV and below). 

Medium-voltage cables (cables with voltage levels of 6kV and above, 35kV and below).

High-voltage cables (cables with voltage levels of 66kV and above).

And cable faults can be divided into open circuit faults, low resistance faults, leakage high resistance faults, and flashover high resistance faults according to their nature.

 

How to judge cable faults

In general, there are three ways to judge the nature of cable faults:

Judge by insulation resistance meter, multi-meter. 

Judge by cable pre-test results. 

Judge by "cable fault tester". Low-resistance and open-circuit faults (high-resistance) can be directly judged by the "low-voltage pulse method" test waveform of a multi-meter or a "cable fault tester".

 

Suitable for testing the faults of various cables

XHGG501-A TDR cable fault locator is a special instrument for measuring and analyzing power cable status and fault distance. It is suitable for testing low resistance, short circuit, open circuit breakage faults, leaking high resistance and flashover high resistance faults of power cables, coaxial cables, street light cables, buried wires, etc. 


Features

 

Pulse width

0.25uS/2uS/4uS  

Minimum resolution

0.1m  

Working conditions

Ambient temperature: -2565; Relative humidity: 90%; 12 Inch Windows System ICE LV TDR Cable Fault Locator 0

Ranging range

68km  


12 Inch Windows System ICE LV TDR Cable Fault Locator 1

The figure above shows the cable fault distance measured by the high-voltage flashover method ICE (ARC single-shot) test method.