Factory Customize Good Price High Voltage Pulse Generator 12kv 800j Low Voltage Cable Fault Locator

Factory Customize Good Price High Voltage Pulse Generator 12kv 800j Low Voltage Cable Fault Locator

제품 상세정보:
원래 장소: 중국
브랜드 이름: XZH Test
인증: CE/ISO
모델 번호: XHHV512-2L
상세 정보
원래 장소:
중국
브랜드 이름:
XZH Test
인증:
CE/ISO
모델 번호:
XHHV512-2L
강조하다:

High Light

강조하다:

12kv high voltage pulse generator

,

800j cable fault locator

,

low voltage cable fault detector

Trading Information
최소 주문 수량:
1 유닛
포장 세부 사항:
나무 상자
배달 시간:
5-8WORK 일
지불 조건:
t/t
공급 능력:
2000Unit/년
제품 설명


XHHV512-2L

Model NO.
XHHV512-12L
Usage
Audio Cable Tester, Coaxial Cable Tester, Digital Cable Tester
Power
Electricity
Certification
CE, ISO
Customized
Customized
Color
Black
Impact Voltage
0~12kv
High Voltage Partial Pressure
2.5
Built-in Capacitor
12μf
Output Voltage Polarity
Negative Polarity
Impact Power
400W
Overcurrent Protection
10A (More Than 3 Seconds)
Over-Temperature Protection
65ºC
Transport Package
Wooden Box with Foam Inside
Specification
540L× 300W× 450H
Trademark
XZH TEST
Origin
China Xi'an
Production Capacity
1000

Product Description




Description
 In low - voltage cable fault testing, for the purpose of shock discharge, the XHHV512 - 12L low voltage pulse generator is often used. Being a tie - rod portable integrated device, it has a humanized design operation mode, uses high - precision dedicated high - voltage electronic components and high - frequency high - voltage technology. These features ensure its ease of operation, light weight and easy transportation.


Panel function description
1. Safety ground: The ground of the instrument shell must be reliably connected to the
ground in order to prevent the instrument shell from being electrified or electric shock to
personnel.
2. High-voltage ground: Also known as high-voltage tail, it must be grounded reliably to
prevent high-voltage leakage and discharge. Poor contact may cause failure to boost
the voltage, high voltage breakdown of the internal components of the instrument, and
safety accidents caused by leakage or discharge inside the instrument.
3. Sampling ground: The negative terminal of the pulse energy storage capacitor has a
high voltage and must be grounded reliably. It is used for sampling when the waveform
is sampled under the high-voltage flashover state of the cable fault tester. (WithoutHigh voltage surge generator
high-voltage flashover sampling, reliable grounding is still required).
4. Discharge button: Press this button to make contact with the ball gap, and discharge
manually. (The duration of each key press cannot exceed 1s).
5. High voltage start button: When the start button light is on, it means that the voltage
output is in the zero position. When the light is on, the start button is valid. If the start
button light is not on after turning on the power switch, turn the voltage adjustment knob
counterclockwise until the light is on. When the button light is on, press this button to
start the device and generate high voltage output.
6. High-voltage stop button: When the test is completed or an abnormality occurs,
press this button to cut off the high-voltage output, the high-voltage light goes out, and
the internal discharge ball stops working. When the stop key is on, it means there is
high voltage output, and when it is off, it means there is no high voltage output.
7. Over-current protection switch: When pressed, it means that the over-current
protection function has started; when it is popped up, it means that the instrument has
triggered the over-current protection.
8. Voltage adjustment: After turning on the device, you must first turn the knob
counterclockwise to the end, press the start button, and then adjust clockwise to
increase the output high voltage from small to large, and adjust counterclockwise to
reduce the output high voltage from large to small.
9. Power switch: "I gear" turns on the AC 220V power supply switch, and "0 gear" turns
off the system power.
10. The fuse holder: the place where the fuse of the AC 220V power supply system is
installed.
11. Power socket: the working power supply of the instrument, AC 220V connection
port.
12. Time setting: Set the discharge time interval.
13. Ammeter: indication of the current on the high voltage side.
14. Voltmeter: high voltage output voltage indicating kV meter.
15. High-voltage output (EMP): When impacting discharge, connect the high-voltage
output line.
16. High voltage output (DC): When DC withstand voltage, connect the high voltage
output line

Technical parameters
 

Impact high voltage 0~12kV
High voltage partial pressure 2.5 level
Built-in capacitor 12μF
Discharge power 0-864J
Output voltage polarity negative polarity
Impact power 250W@peak
Working mode Selectable or adjustable impulse rate and Single shot
Length of test cable The high-voltage output line of the pull-rod type high-voltage pulse generator is 2 meters long, the ground line is 3 meters long, and the power line is 1.8 meters long. 
Minimum Output current in DC mode 30mA at 12kV
Over temperature protection 65ºC
Over current protection 8mA (more than 3 seconds)
Volume(mm) 540L×300W×450H
Weight not more than 25kg
Power supply AC220V±15%, 50Hz±2Hz(60Hz) 
Ambient temperature -20~+60ºC
Packing List