XHHD530M 


Description

The hidden buried line fault detector is a dedicated instrument for power - related sectors, industrial and mining areas, and rural regions to locate underground cables and detect their faults. It identifies cable direction, position, burial depth, and faults (leakage, broken core, etc.), and detects above - ground waterproof wires/cables with proper methods.


Transmitter

The transmitter panel is equipped with "power switch", "power indication"; "output selection", "high, medium, low"; "output indication" and "K measurement" switching switches, and the indicator light indicates the switching position; "output·KΩ measurement" shares an output terminal, which is switched by the "output·indication" and "KΩ measurement" switches; set "output 2" output terminal; square meter head indicates output and KΩ resistance. It can check the line on, off, mixed, and measure the size of the ground leakage resistance.

Output signal form

pulse period 1.34±0.15mS. Width 0.2 ±0.1mS intermittent period 1.8±1S.

Output voltage

pulse period Upp high range greater than 1000V, medium range greater than 60V, low range greater than 30V.

KΩ measurement

It can check the side line on, off, mixed and leakage group size, and determine the nature of the fault.

The "output 2" output terminal

It can output peak pulse short-circuit current 1-5A.

Output power

Pulse power greater than 2.5W (when high-end load resistance is 80KΩ).

Power supply

8.4V.




Low Voltage Tester Fault Locator 0

Instrument principle and structure

This instrument consists of a transmitter, a receiver, a probe and a head, a pair of plugs and plugs, connecting wires, etc.

Transmitter (1) Mainly outputs continuous pulse signals, which is the signal source for finding faults. (2) kΩ function, can detect the continuity, disconnection, mixing and leakage resistance of the line, and determine the nature and type of fault. (3) "Output 2" output terminal outputs large current

Low Voltage Tester Fault Locator 1

Packing list

Item

Name

Qty.

1

Transmitter

1

2

Receiver

1

3

Probe

1

4

Probe head

1

5

Insert rod(red black)

2

6

Connection lines

2

7

Charger

1